A spare pair of CAN transceiver boards arrived in the mail today. I didn't need them, since the two I already had were enough, but they got me to finally run a test I had been putting off. The eight-motor robot will put its front legs on one CAN bus and its rear legs on a second one, with the Teensy driving both. Until tonight that was only a plan and a firmware sketch that had never been loaded onto hardware.

Double bus test
The leg's two motors normally share one cable. The knee gets its power and its CAN signal through the hip motor's second socket. To test two buses with only two motors, I unplugged that cable and gave the knee its own short pigtail, with power from the same supply and the CAN wires going to a second transceiver board on the Teensy's other CAN controller. Hip on bus A, knee on bus B. It took me a while to wire up, mostly because everything is still jumper wires on breadboards.

Then I flashed the new two-bus firmware for the first time. It scanned both buses and found the hip on A and the knee on B, with a note that the knee was not on its planned bus, which is exactly right for this bench setup. Both motors reported about 47.6 V, no faults, and the same current-loop gain I measured weeks ago.
Streaming test
The firmware has a test mode that enables the motors with all gains at zero, so they stay limp, and then sends one command frame to every motor on both buses at 500 Hz while counting every reply and every bus error. I ran it for a minute, then for ten. In the ten-minute run each bus carried 300,000 frames, every single one was answered, and both buses finished with zero errors. The motors warmed from 16 to 21 °C just sitting there enabled, and made a faint whine the whole time with nothing moving.
One number surprised me. The bench supply read about 0.12 A for the two enabled motors, which is around 60 mA each. The idle figure I had been using came from motors that were powered but not enabled, and it was about a quarter of that. So eight motors standing enabled will draw about half an amp before doing any work.
Two ways to fail
The part I actually wanted to see was the safety code. A simulation earlier in the project showed that if one leg's motor stops responding mid-jump and nothing notices for 20 ms, the robot falls without the firmware ever knowing. So the two-bus firmware tracks the age of every motor's last reply and aborts if any motor goes quiet for 10 ms, and it also aborts on any fault bit a motor reports. Neither path had ever been triggered on real hardware.
First test: with the frames streaming, I switched the 48 V supply off. The firmware stopped within the same tick on an under-voltage fault from the knee, ran its shutdown sequence into two buses that no longer had anyone to acknowledge the frames, printed its report, and came back to the prompt. When I switched the power back on, both motors answered a rescan with their faults cleared. No reset needed.
Second test: with the frames streaming again, I pulled one of the 3.3 V logic wires off the knee's transceiver board. The knee itself stayed powered and kept answering, but the Teensy could no longer hear it. The firmware stopped on "knee silent for 10 ms" after exactly five missed replies, which is the earliest it is allowed to trip. That bus had gone into the CAN bus-off state from the disconnected wire, and the next scan after plugging the wire back in cleared it on its own.
Takeaways
The two-bus plan works on real hardware, and both abort paths do what they were written to do. There is one test left in this series that I ran out of time for tonight: putting both motors on one bus with a single 60 Ω termination at the middle, which is how the robot's body will be wired, and streaming at 1 kHz for ten minutes to see whether that termination holds up. A circuit simulation this week suggested it might ring, so I want the real answer before eight motors are on the table.